| 0001469 | K18X001.00 SKB SWAN | HW | public | 2022-04-28 11:33 | 2025-04-11 21:33 |
| Reporter | (HW) Tom Lee | Assigned To | (ALTech) SH Son | Due Date | |
| Priority | normal | Severity | s3-moderate | Reproducibility | have not tried |
| Status | closed | Resolution | fixed | ||
| Summary | 0001469: There seems to be a quality difference issue between MP adaptors. | ||||
| Description | Fii test conduction for 2nd build sample of 2nd source, found SWAN + sample NO.0 MP adaptor is fail, SWAN + sample No.1 and No.2 MP adaptors are pass. There seems to be a quality difference issue between MP adaptors. | ||||
| Tags | No tags attached. | ||||
| Attach Tags | |||||
| User List |
(ALTech) Lonnie Kim , (ALTech) SY Yoon , (HW) Sean Chiang , (HW) Tom Lee |
|---|
|
|
|
|
|
Hi Tom Could you please send the No.0 adaptor? I will request the analyze to the adaptor vender. Thanks SON |
|
|
Hi, SH No problem. Please provide ALT's FedEx account to me. Thanks ~ Tom |
|
|
Hi Mr.Yoon, As mentioned in the weekly meeting last Friday, the failed CE may be an risk for current MP product. I think we should clarify the root cause of the defective PSU found in our side. Have you informed the supplier about this? We are waiting for your confirmation & FedEX account to send back the defective unit. Thanks, Regards, Sean |
|
|
Hi, Sean I have question about CE fail. Do you means EMC CE or CE certification? If CE certification, that daptor dpn't need to CE test. Why did you test CE? Best regards Lonnie Kim |
|
|
Hi Lonnie, I mean EMC Conduction Emission test. Regards, Sean |
|
|
Hi Tom The adapter ce conduction test failed. We requested 8D report to adapter vendor Regards Joung |
|
|
Hi Tom The update of test result of root cause to conduction issue from adapter vendor up to now Regards joung |
|
|
Hi Tom The update of test result of 10EA Sample production by production plant. Regards. Joung |
|
|
Hi Tom The update of test result of 10EA Sample production by production plant. Regards. Joung |
|
|
Hi Tom Efficacy evaluation test results of updated report attached . Regards joung |
|
|
Hi, Joung reply 0001469:0011124 The file was corruption, lack of page 18 / 20 / 21. Please re-upload the file. Thanks ! Tom |
|
|
Hi Tom The EMI fail report is re-upload . Regards joung |
|
|
No more action. So, close this issue. |
| Date Modified | Username | Field | Change |
|---|---|---|---|
| 2022-04-28 11:33 | (HW) Tom Lee | New Issue | |
| 2022-04-28 11:33 | (HW) Tom Lee | Status | new => assigned |
| 2022-04-28 11:33 | (HW) Tom Lee | Assigned To | => (ALTech) SH Son |
| 2022-04-28 11:33 | (HW) Tom Lee | File Added: BFX-UA300 2nd build sample conduction test result.pdf | |
| 2022-04-28 11:37 | (HW) Tom Lee | Issue Monitored: (HW) Tom Lee | |
| 2022-04-28 11:37 | (HW) Tom Lee | Severity | s2-severe => s3-moderate |
| 2022-04-28 11:37 | (HW) Tom Lee | Description Updated | |
| 2022-04-28 11:38 | (HW) Tom Lee | Issue Monitored: (HW) Sean Chiang | |
| 2022-04-28 11:40 | (HW) Tom Lee | Issue Monitored: (ALTech) Lonnie Kim | |
| 2022-04-28 11:40 | (HW) Tom Lee | Issue Monitored: (ALTech) SY Yoon | |
| 2022-04-28 11:56 | (ALTech) SH Son | Note Added: 0009943 | |
| 2022-04-28 16:05 | (HW) Tom Lee | Note Added: 0009945 | |
| 2022-05-04 12:54 | (HW) Sean Chiang | Note Added: 0009961 | |
| 2022-05-04 13:09 | (ALTech) Lonnie Kim | Note Added: 0009963 | |
| 2022-05-04 13:38 | (HW) Sean Chiang | Note Added: 0009964 | |
| 2022-06-24 08:40 |
|
File Added: adapter ce fail conduction test.pdf | |
| 2022-06-24 08:40 |
|
Note Added: 0010240 | |
| 2022-06-24 08:51 | (ALTech) SY Yoon | Note Edited: 0010240 | |
| 2022-08-19 16:10 |
|
Note Added: 0010667 | |
| 2022-08-19 16:10 |
|
File Added: LA-B271KS ADAPTOR(24V 4A) EMI fail report_220819.pptx | |
| 2022-09-20 07:55 |
|
Note Added: 0010896 | |
| 2022-09-20 07:56 |
|
Note Edited: 0010896 | |
| 2022-09-20 07:59 |
|
Note Added: 0010897 | |
| 2022-09-20 07:59 |
|
File Added: LA-B271KS ADAPTOR(24V 4A) EMI fail report_2200920.pptx | |
| 2022-09-20 08:28 |
|
Note View State: 0010896: private | |
| 2022-09-20 08:29 |
|
Note View State: 0010896: public | |
| 2022-10-28 08:08 |
|
Note Added: 0011124 | |
| 2022-10-28 08:08 |
|
File Added: LA-B271KS ADAPTOR(24V 4A) EMI fail report_221027.pptx | |
| 2022-10-28 19:06 | (HW) Tom Lee | Note Added: 0011131 | |
| 2022-10-31 10:06 |
|
Note Added: 0011133 | |
| 2022-10-31 10:06 |
|
File Added: LA-B271KS ADAPTOR(24V 4A) EMI fail report_221027.pdf | |
| 2022-10-31 10:06 |
|
File Added: Efficacy evaluation EMI TEST results.xlsx | |
| 2022-10-31 10:06 |
|
File Added: EMI TEST DATA (220915).zip | |
| 2025-04-11 21:33 | (HW) Sean Chiang | Status | assigned => closed |
| 2025-04-11 21:33 | (HW) Sean Chiang | Resolution | open => fixed |
| 2025-04-11 21:33 | (HW) Sean Chiang | Note Added: 0017482 |